- PRODUCTS
- MODEL LIST
- APPLICATIONS
- SUPPORT
- SALES/SERVICE
- BLOG
- ABOUT
Housing | Pressure Sensor/Range | Connectors | Communications | Pump |
1 – 600 m (plastic) | 1 – 20 m strain gauge | 1 – XSG/AG | 0 – RS-232 | 1 - SBE 5M |
2 – 7000 m (titanium) | 2 – 100 m strain gauge | 2 – MCBH | 2 - SBE 5P/5T | |
3 – 10,500 m (titanium) | 3 – 350 m strain gauge | |||
4 – 600 m strain gauge | ||||
5 – 1000 m strain gauge | ||||
6 – 2000 m strain gauge | ||||
7 – 3500 m strain gauge | ||||
8 – 7000 m strain gauge | ||||
9 – 10,500 m strain gauge | ||||
A – 45 psia Digiquartz | ||||
B – 100 psia Digiquartz | ||||
C – 200 psia Digiquartz | ||||
D – 300 psia Digiquartz | ||||
E – 400 psia Digiquartz | ||||
F – 1000 psia Digiquartz | ||||
G – 2000 psia Digiquartz | ||||
H – 3000 psia Digiquartz | ||||
I – 6000 psia Digiquartz | ||||
J – 10,000 psia Digiquartz | ||||
K – 15,000 psia Digiquartz |
Example: 19P.28201 is an SBE 19plus V2 with 7000 m housing, 7000 m strain gauge pressure sensor, MCBH connectors, RS-232 communications, and SBE 5M pump. See table below for description of each selection:
PART # | DESCRIPTION | NOTES |
19plus V2 |
SeaCATplus Version 2 Profiler Pumped Conductivity, Temperature, Depth Recorder - 4 Hz sampling rate, includes submersible pump, 64 MB memory, 6 differential A/D channels (0 - 5 volt input range), 1 RS-232 data input channel, data I/O and pump Y-cable, 2.5 meter data I/O cable, Seasoft software, & complete documentation. Configurations that include pumped SBE 43 or other pumped auxiliary sensors require SBE 5T or 5P. Order protective cage separately. |
19plus V2 is intended primarily as a profiling CTD, sampling at 4 Hz, but can also be used in moored mode to obtain long-term time series data. 19plus V2 is powered by internal batteries, & records data in memory. In addition, in profiling mode, 19plus V2 can be deployed:
Notes:
|
SBE 19plus V2 Housing (depth) Selections — MUST SELECT ONE | ||
19P.1xx0x | 600 m plastic housing | |
19P.2xx0x | 7000 m titanium housing | |
19P.3xx0x | 10,500 m titanium housing | |
SBE 19plus V2 Pressure Sensor Selections — MUST SELECT ONE | ||
19P.x1x0x | 20 m strain gauge pressure sensor | Pressure sensor is installed in connector end cap, & is not field replaceable / swappable. While highest pressure rating gives you most flexibility in using 19plus V2, it is at expense of accuracy & resolution. It is advantageous to use lowest range pressure sensor compatible with your intended maximum operating depth, because accuracy & resolution are proportional to pressure sensor's full scale range. For example, comparing 2000 & 7000 m sensors:
|
19P.x2x0x | 100 m strain gauge pressure sensor | |
19P.x3x0x | 350 m strain gauge pressure sensor | |
19P.x4x0x | 600 m strain gauge pressure sensor | |
19P.x5x0x | 1000 m strain gauge pressure sensor | |
19P.x6x0x | 2000 m strain gauge pressure sensor | |
19P.x7x0x | 3500 m strain gauge pressure sensor | |
19P.x8x0x | 7000 m strain gauge pressure sensor | |
19P.x9x0x | 10,500 m strain gauge pressure sensor | |
19P.xAx0x | 45 psia (20 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version) | Digiquartz pressure sensors provide better accuracy (0.02% of full scale range vs 0.1% of full scale range) & resolution (Digiquartz resolution dependent on user-programmable integration time) than strain gauge pressure sensors. See strain gauge options above for photo of pressure sensor port; when used with Digiquartz, nylon pressure capillary fitting screws into port.
Pressure sensor is installed in connector end cap, & is not field replaceable / swappable. While highest pressure rating gives you most flexibility in using 19plus V2, it is at expense of accuracy & resolution. It is advantageous to use lowest range pressure sensor compatible with your intended maximum operating depth, because accuracy & resolution are proportional to pressure sensor's full scale range. For example, comparing 2000 psia (1400 m) & 6000 psia (4200 m) sensors:
Note: 19plus V2 can only sample at 2 Hz (instead of 4 Hz) when equipped with Digiquartz pressure sensor. Additionally, 19plus V2 with Digiquartz pressure sensor is approximately 19 cm longer than strain gauge version, and requires a different cage (see PN 801270 under Spares & Accessories below). |
19P.xBx0x | 100 psia (60 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version) | |
19P.xCx0x | 200 psia (130 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version) | |
19P.xDx0x | 300 psia (200 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version) | |
19P.xEx0x | 400 psia (270 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version) | |
19P.xFx0x | 1000 psia (680 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version) | |
19P.xGx0x | 2000 psia (1,400 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version) | |
19P.xHx0x | 3000 psia (2,000 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version) | |
19P.xIx0x | 6000 psia (4,200 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version) | |
19P.xJx0x | 10,000 psia (6,800 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version) | |
19P.xKx0x | 15,000 psia (10,500 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version) | |
SBE 19plus V2 Connector Selections — MUST SELECT ONE | ||
19P.xx10x | XSG/AG connectors on SeaCAT bulkhead connectors, data I/O and pump Y-cable, and data I/O cable |
Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to XSG/AG connectors. Like XSG/AG connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets. |
19P.xx20x | Wet-pluggable (MCBH) connectors on SeaCAT bulkhead connectors, data I/O and pump Y-cable, and data I/O cable | |
SBE 19plus V2 Submersible Pump Selections — MUST SELECT ONE | ||
19P.xxx01 | SBE 5M pump |
SBE 5M pump is intended for providing pumped conductivity only, for improved conductivity response over non-pumped configuration. SBE 5M pump with plastic housing is supplied for 19plus V2 with 600 m housing; SBE 5M pump with titanium housing is supplied for 19plus V2 with 7000 or 10,500 m housing. Larger, more powerful SBE 5P or 5T is required if also planning to pump auxiliary sensors (such as dissolved oxygen, etc.). Operational characteristics of SBE 5P & 5T are identical. SBE 5P plastic pump is supplied for 19plus V2 with 600 m housing; SBE 5T titanium pump is supplied for 19plus V2 with 7000 or 10,500 m housing. SBE 5M or 5P/5T selection includes pump (with same connector type as 19plus V2), pump mount, & data I/O - pump Y-cable (cable compatible with connectors on 19plus V2 and pump). See cable DN 31551 for XSG/AG connectors, DN 32896 for wet-pluggable connectors. |
19P.xxx02 | SBE 5P/5T pump | |
SBE 19plus V2 Auxiliary Sensor & Integration Options | ||
19p-6a | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), with XSG connector, 7000 m (cable & mount included, requires 19p-4b & 19P.xx10) |
General Information:
Sensor-Specific Information:
Moored Application Information:
|
19p-6b | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), with Wet-pluggable connector, 7000 m (cable & mount included, requires 19p-4b & 19P.xx20) | |
19p-6c | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), with XSG connector, 600 m plastic (cable & mount included, requires 19p-4a or -4b & 19P.xx10) | |
19p-6d | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration) with Wet-pluggable connector, 600 m plastic (cable & mount included, requires 19p-4a or -4b & 19P.xx20) | |
19p-7a | SBE 18 pH sensor, for use in profiling mode only, with XSG connector, 1200 meter (cable and mount included; requires 19P.xx10) | |
19p-7b | SBE 18 pH sensor, for use in profiling mode only, with Wet-pluggable connector, 1200 meter (cable and mount included; requires 19P.xx20) | |
19p-8a | SBE 27 pH/ORP sensor, for use in profiling mode only, with AG connector, 1200 meter (cable and mount included; requires 19P.xx10) | |
19p-8b | SBE 27 pH/ORP sensor, for use in profiling mode only, with Wet-pluggable connector, 1200 meter (cable and mount included; requires 19P.xx20) | |
YMOLD | Extra charge for Y-cable to connect two (2) or more sensors to one (1) auxiliary sensor input bulkhead connector on CTD | |
19p-9a | Underwater power/data interface module ( PDIM) with XSG connectors, integrated for use with SBE 36 CTD Deck Unit or 33 Carousel Deck Unit (includes PDIM, interface cable, and mounting hardware; requires 19P.xx10) |
SBE 36 CTD Deck Unit & PDIM provide surface power & real-time data acquisition & control for 19plus V2, allowing deployment with 10,000 m long single-conductor sea cables. SBE 36 is installed on ship, while PDIM is mounted on or near 19plus V2. |
19p-9b | Underwater power/data interface module ( PDIM) with Wet-pluggable connectors, integrated for use with SBE 36 CTD Deck Unit or 33 Carousel Deck Unit (includes PDIM, interface cable, and mounting hardware; requires 19P.xx20) | |
SBE 19plus V2 Spares & Accessories | ||
801269 Buy Now |
Stainless-steel protective cage, 40 in. (101 cm) tall (SeaCATplus) | Many users purchase optional cage to protect system from damage during deployment.
See document 67171 for installation details. Notes:
|
801270 Buy Now |
Stainless-steel protective cage, 48 in. (123 cm) tall (SeaCATplus with Digiquartz) | |
50396 Buy Now |
Stainless-steel protective cage, 38 in. (96 cm) tall, used in SBE 32 Carousel CTD extension stand | |
50434 Buy Now |
SBE 16plusV2/19plusV2 Spares Kit ( XSG/AG connectors) - Complete support kit containing spare data I/O cable, bulkhead connectors, dummy plugs, Triton X-100, o-ring lubricant, & other mechanical spares & maintenance items. | Order appropriate spares kit for connector type on 19plus V2: |
50435 Buy Now |
SBE 16plusV2/19plusV2 Spares Kit ( Wet-pluggable connectors) - Complete support kit containing spare data I/O cable, bulkhead connectors, dummy plugs, Triton X-100, o-ring lubricant, & other mechanical spares & maintenance items. | |
801511 | 9 NiMH cells in rechargeable drop-in pack (108v/8.0 Ah) |
19plus V2 comes standard with alkaline batteries, but can be powered with rechargeable NiMH batteries instead. Batteries are easily accessed by unscrewing battery end cap. |
90900S Buy Now |
NiMH Battery Charger for 6, 9, or 12-cell/8.0 Ah D-cell packs. Provides full recharge in 2 hours, includes AC power cord and battery charging cable. | |
50288 |
SBE 19plus/19plusV2 Moored Mode Conversion Kit - anti-foulant holders and hardware for user conversion from profiling to moored mode configuration. AF24173 anti-foulant devices (PN 801542) are NOT included. Note: When installed on 19plus/19plusV2 at time of order, the T-C Duct and related parts normally installed on profilers are provided as a separate Profiling Conversion Kit, PN 50345 (order 801542 anti-foulant devices separately) |
19plus V2 is intended primarily for use as profiling instrument, & does not come standard with anti-foulant device fittings. Conversion kit allows user to retrofit 19plus V2 with anti-foulant device fittings for moored applications. Anti-foulant device fittings attach to each end of conductivity cell. See document 67114. Only 1 conversion kit is needed per instrument; order replacement Anti-Foulant Devices as needed (see next item). |
801542 | AF24173 Anti-Foulant Device pair (spare, bagged, labeled for shipping) | Anti-foulant devices fit into anti-foulant device cups at each end of conductivity cell. Anti-foulant devices included with standard shipment; these are spares. Useful life varies, depending on several factors. We recommend that customers consider more frequent replacement when high biological activity & strong current flow (greater dilution of anti-foulant concentration) are present. Moored instruments in high growth & strong dilution environments have been known to obtain a few months of quality data, while drifters that operate in non-photic, less turbid deep ocean environments may achieve years of quality data. Experience may be strongest determining factor in specific deployment environments. |
20200 | USB to Serial Port Adapter, FTDI UC232R-10 (connects computers with USB ports to RS-232 instruments) | Many newer PCs & laptop computers have USB port(s) instead of RS-232 serial port(s). USB serial adapter plugs into USB port, & allows a serial device to be connected through adapter. Multi-port adapters are available from other companies; see Application Note 68. |
31634 | Hardigg shipping case (AL4915-1105), for SBE 19plus/19plus V2 in optional cage | Hardigg shipping case with custom foam inserts holds SBE 19plus V2 with auxiliary sensors in optional cage ( SBE 9plus shown; SBE 19plus V2 similar).
Order 31634 for 19plus V2 with strain-gauge pressure sensor; order 31842 for 19plus V2 with Digiquartz pressure sensor (19plus V2 with Digiquartz requires a longer cage - PN 801270 - which does not fit in PN 31634 shipping case). Notes regarding features of Hardigg case supplied by Sea-Bird: |
31842 | Hardigg shipping case (AL6815-1105), for SBE 19plus/19plus V2 with Digiquartz in optional cage | |
50275 Buy Now |
SBE 19plus/19plus V2 magnetic switch assembly | Replacement for magnetic switch, which is used to start & stop logging. See document 67101. |
41124 Buy Now |
Battery cover/contact plate, replaces 80076.1 | Cover plate for alkaline batteries. |
801385 | Data I/O cable, RMG-4FS with DB-9S & power leads, 2.4 m (DN 32277) |
These test cables are used for setting up system & uploading data from memory after recovery. Data I/O cable connects to 4-pin end of pump-data I/O Y-cable. Connector type (RMG or wet-pluggable) must match 19plus V2 connector type. Applicable cable is included with 19plus V2; these are spares. |
801374 | Data I/O cable, Wet-pluggable (MCIL-4FS) with DB-9S, 2.4 m (DN 32715) | |
17709 | Y-cable, Pump-Data I/O, XSG/AG connectors (DN 31551) |
These Y-cables connect 6-pin data I/O - pump bulkhead connector to pump (2-pin leg) & to data I/O cable (4-pin leg). Connector type (XSG/AG or wet-pluggable) must match 19plus V2 connector type. Applicable cable is included with 19plus V2; these are spares. |
171883 | Y-cable, Pump-Data I/O, Wet-pluggable connectors (DN 32896) | |
23170 Buy Now |
Seacat/Searam battery endcap handle (DN 20220) | |
23114 Buy Now |
Seacat/Searam battery endcap lifting eye (DN 20217) | |
231787 | Seacat connector guard, titanium (DN 21910) | Typically used for SBE 19plus V2 deployed without a cage. |
90087 Buy Now |
Universal plumbing kit (includes pump air release valve, Y-fitting, & tubing) - Application Note 64-1 | Application Note 64-1 details installation of plumbing for SBE 43 & pump on a CTD. |
30411 | Triton X-100 cleaning solution, 500 ml bottle | |
50087 Buy Now |
Cell filler/storage device with hose barbs ( Application Note 34) | For cleaning conductivity cell after each use & storing instrument between uses. See document 67043 & Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells. |
various | Plumbing | For assorted sizes of Tygon tubing, see SBE 5M or 5P or 5T Configuration. |
Underwater Cable for Hand-Hauled, Real-Time Profiling (see Application Note 59 for proper use and limitations) | ||
801150 | Load-bearing Data cable, XSG connector with DB-9S, 100 feet (30 m) (DN 32284) |
These cables are for hand-hauling 19plus V2 & acquiring real-time data. Cables are not intended for static working loads above 45 kg (100 lbs); working loads above 18 kg (40 lbs) may be difficult to handle without winch. Minimum recommended cable bend radius is 10 cm (4 in.) (e.g., 20 cm sheave block nominal diameter). See Application Note 59: A Load-Bearing Underwater Cable for Hand-Hauled, Real-Time Profiling. Select a cable with connector (XSG or wet-pluggable MCBH) to match your 19plus V2. |
801295 | Load-bearing Data cable, XSG connector with DB-9S, 165 feet (50 m) (DN 32284) | |
801140 | Load-bearing Data cable, XSG connector with DB-9S, 200 feet (61 m) (DN 32284) | |
801153 | Load-bearing Data cable, XSG connector with DB-9S, 330 feet (100 m) (DN 32284) | |
801301 | Load-bearing Data cable, XSG connector with DB-9S, 415 feet (126 m) (DN 32284) | |
801148 | Load-bearing Data cable, XSG connector with DB-9S, 600 feet (183 m) (DN 32284) | |
801371 | Load-bearing Data cable, Wet-pluggable with DB-9S, 100 feet (30 m) (DN 32643) | |
801372 | Load-bearing Data cable, Wet-pluggable with DB-9S, 200 feet (60 m) (DN 32643) | |
801337 | Load-bearing Data cable, Wet-pluggable with DB-9S, 330 feet (100 m) (DN 32643) | |
801338 | Load-bearing Data cable, Wet-pluggable with DB-9S, 660 feet (200 m) (DN 32643) |