Try our new Cable Search page -- this Beta page allows you to search for cables, including Y-cables for multiple auxiliary sensors connecting to a single end cap connector.
This list includes our most commonly used cables. The actual cable required is dependent on the instrument as well as the combination of auxiliary sensors used with it; y-cables may be required when connecting multiple auxiliary sensors to your CTD. (comparison of Standard XSG/RMG connectors to wet-pluggable MCBH connectors).
To ensure that you are purchasing the correct cable, consult Sea-Bird with your instrument's serial number and information about your instrument configuration / features before placing an order. (Click here to see where to find the serial number on your instrument.)
Cables are listed two ways below:
The Sea-Bird part number and drawing number is listed for each cable; the
drawing number is linked to the cable drawing.
Check the drawing if the cable length listed on this page does not meet
your needs; cable drawings often list part numbers for the same cable in other
lengths.
Notes:
1. We do not publish prices on the website. Please contact us for pricing (seabird@seabird.com
or 425-643-9866).
2. Y-cables for auxiliary sensors are not listed; please contact us for
part numbers and pricing, or try the new Cable
Search page.
Sea-Bird Instruments (click the instrument in the list below or scroll through the page to find the desired instrument):
Generic Cable List (click the item in the list below or scroll through the page to find the desired item):
Links to other Sales pages:
SBE 11plus Deck Unitpigtail to seacable, part # varies depending on length (Standard connector), DN 30579
pigtail to seacable, part # varies depending on length (optional Wet-pluggable connector), DN 32514
seacable extension, part # varies depending on length (Standard connectors), DN 30588
seacable extension, part # varies depending on length (optional Wet-pluggable connectors), DN 32763
to SBE 3 or SBE 4 (Standard connectors), part #17086 (0.64 m), DN 30566
to SBE 3 or SBE 4 (optional Wet-pluggable connectors), part #171669 (0.76 m), DN 32671
to SBE 5T (Standard connectors), part #17133 (1.12 m), DN 30565
to SBE 5T (optional Wet-pluggable connectors), part #171503 (1.12 m), DN 32499
to SBE 5T, part #17799 (y-cable for dual pumps, Standard connectors), DN 31522
to SBE 5T, part #171671 (y-cable for dual pumps, optional Wet-pluggable connectors), DN 32673
to SBE 11plus (from 9plus with Standard connectors), part #80591 (2.4 m) or 80915 (10 m), DN 31314
to SBE 11plus (from 9plus with optional Wet-pluggable connectors), part #801363 (2.4 m), DN 32695
to SBE 13 (Standard connectors), part #17546 (1.27 m), DN 31331
to SBE 17plus (Standard connectors), part #17132 (0.33 m), DN 30568
to SBE 17plus (optional Wet-pluggable connectors), part #171796 (0.33 m), DN 32758
to SBE 18 (Standard connectors), part #17474 (0.76 m), DN 30918
to SBE 27 (Standard connectors), part #17898 (0.76 m), DN 31749
to SBE 32 (Standard connectors), part #17198 (2 m), DN 30568
to SBE 32 (optional Wet-pluggable connectors), part #171741 (2 m), DN 32758
to SBE 35 or 35RT (Standard connectors), part #171220 Y-cable (SBE 9plus/35/32), DN 32208
to SBE 35 or 35RT (optional Wet-pluggable connectors), part #171995 Y-cable (SBE 9plus/35/32), DN 32963
to SBE 43 (Standard connectors), part #171491 (0.76 m), DN 32496
to SBE 43 (optional Wet-pluggable connectors), part #172218 (0.76 m), DN 32654
to Bottom Contact Switch (Standard connectors, male bulkhead connector on 9plus), part #17133 (1.12 m), DN 30565
to Bottom Contact Switch (Standard connectors, female bulkhead connector on 9plus), part #172267 (1.12 m), DN 33200
to Bottom Contact Switch (optional Wet-pluggable connectors, female bulkhead connector on 9plus), part #172270 (1.12 m), DN 33201
to Benthos/Datasonics PSA-916 (from 9plus Standard connector), part #171130 (1.8 m), DN 32075
to Benthos/Datasonics PSA-900 (from 9plus Standard connector), part #17437 (1.8 m), DN 30864
to Biospherical QSP-200L or QSP-2300L (from 9plus Standard connector), part #17610 (2 m), DN 30701
to Chelsea AquaTracka or AlphaTracka (from 9plus Standard connector), part #17602 (1.2 m), DN 31253
to D&A OBS-3 (from 9plus Standard connector), part #17361 (0.76 m), DN 30954
to D&A OBS-3+ (from 9plus Standard connector), High & Low range, part #172130 (1 m), DN 33080
to D&A OBS-3+ (from 9plus optional Wet-pluggable connector), High & Low range, part #172131 (1 m), DN 33081
to D&A OBS-3+ (from 9plus Standard connector), Low range (1X), part #172109 (1 m), DN 33058
to D&A OBS-3+ (from 9plus optional Wet-pluggable connector), Low range (1X), part #172111 (1 m), DN 33060
to D&A OBS-3+ (from 9plus Standard connector), High range (4X), part #172110 (1 m), DN 33059
to D&A OBS-3+ (from 9plus optional Wet-pluggable connector), High range (4X), part #172112 (1 m), DN 33061
to G.O. 1015 Rosette (from 9plus Standard connector), part #17196 (reverse polarity) (2.5 m), DN 30566
to G.O. 1015 Rosette (from 9plus Standard connector), part #17533 (normal polarity) (2.4 m), DN 31315
to Satlantic SatPAR (from 9plus Standard connector), part # 172215 (2 m), DN 32628
to Satlantic SatPAR (from 9plus Wet-pluggable connector), part # 172214 (2 m), DN 32654
to Seapoint fluorometer or turbidity meter (1X) (from 9plus Standard connector), part #171099 (1.1 m), DN 32073
to Seapoint fluorometer or turbidity meter (3X/5X) (from 9plus Standard connector), part #171147 (1.1 m), DN 32101
to Seapoint fluorometer or turbidity meter (10X/20X) (from 9plus Standard connector), part #172221 (1.1 m), DN 31933
to Seapoint fluorometer or turbidity meter (30X/100X) (from 9plus Standard connector), part #171845 (1.1 m), DN 31924
to Turner Cyclops-7 (1X) (from 9plus Standard connector), part #171908 (1.1 m), DN 32910
to Turner Cyclops-7 (10X) (from 9plus Standard connector), part #171907 (1.1 m), DN 32909
to Turner Cyclops-7 (100X) (from 9plus Standard connector), part #171909 (1.1 m), DN 32911
to Turner SCUFA (from 9plus Standard connector), part #171418 (1.1 m), DN 32417
to WET Labs C-Star or WETStar with old-style 4-pin connector (from 9plus Standard connector), part #17876 (1.1 m), DN 31725
to WET Labs ECO-AFL, ECO-FL, C-Star, or WETStar with new-style 6-pin connector (from 9plus Standard connector), part #171953 (1.1 m), DN 32491
to WET Labs ECO-AFL, ECO-FL, C-Star, or WETStar with new-style 6-pin connector (from 9plus Wet-pluggable connector), part #172437 (1.1 m), DN 32853
to WET Labs ECO-FL-NTUS or ECO-FL-NTU(RT) (from 9plus Standard connector), part #171869 (1.1 m), DN 32812
to WET Labs ECO-FL-NTUS or ECO-FL-NTU(RT) (from 9plus Wet-pluggable connector), part #172285 (1.1 m), DN 32846
to SBE 9plus (with Standard connectors) (test cable) (from SBE 11 Sea Cable), part #80591 (2.4 m) or 80915 (10 m), DN 31314to SBE 9plus (with optional Wet-pluggable connectors) (test cable) (from SBE 11 Sea Cable), part #801363 (2.4 m), DN 32695
to slip ring (from SBE 11 Sea Cable), part # varies depending on length, DN 31371
to computer COM port (from SBE 11 Interface [RS-232] or SBE 11 Modem Channel), part #171886 (3 m) -- for older 25-pin connector on SBE 11plus V2
to computer COM port (from SBE 11 Interface [RS-232] or SBE 11 Modem Channel), part #171887 (3 m) -- for current 9-pin connector on SBE 11plus V2
to computer COM port (from SBE 11 Interface [IEEE-488]), part #17082 -- for older 25-pin connector on SBE 11plus V2
to NMEA simulation computer COM port (from SBE 11 NMEA Input), part #801422 (1.8 m), DN 32786
to computer COM port (from SBE 11 Remote Out, for setup), part #801429 (1.8 m), DN 32799
to Surface PAR QSR-2200 or QCR-2200 with Switchcraft connector (from SBE 11 Surface PAR Input), part #801367 (15 m), DN 32704
to Surface PAR QSR-240 or QCR-240 with Bendix connector (from SBE 11 Surface PAR Input), part #80665 (30 m), DN 31475
to Surface PAR QSR-240 or -2200 or QCR-240 or -2200 with Lemo connector (from SBE 11 Surface PAR Input), part #801238 (30 m), DN 32434
to SBE 14 (from SBE 11 Remote Out), part #801237 (100 m), DN 32433
to computer COM port (from SBE 11 Serial Data Uplink or 9600 Baud Uplink), null modem cable, part #171890 (3 m)
(replaces part #801428, DN 32798)to AC power supply (U.S. Standard), part #17015
SBE 16plus V2 and 16plus (no longer in production) SeaCAT Conductivity & Temperature (P optional) Recorderto computer COM port, part #801437 (100 m), DN 32809
to SBE 11plus V2, part #801237 (100 m), DN 32433
SBE 16plus-IM V2 and 16plus-IM (no longer in production) SeaCAT Conductivity & Temperature (P optional) Recorderto computer COM port (from Standard connector), part #801225 (2.4 m), DN 32421
Note: For 16plus V2, 801225 connects to either data I/O extension cable 17762 (when 16plus V2 configured without a pump) or to 4-pin end of Y-cable 17797 (when 16plus V2 configured with a pump).to computer COM port (from optional Wet-pluggable connector), part #801374 (2.4 m), DN 32715
Note: For 16plus V2, 801374 connects to either data I/O extension cable 172393 (when 16plus V2 configured without a pump) or to 4-pin end of Y-cable 172220 (when 16plus V2 configured with a pump).Data I/O extension cable (Standard connectors), 6-pin to 4-pin, part #17762 (0.84 m), DN 31605 -- only applicable to 16plus V2
Data I/O extension cable (optional Wet-pluggable connectors), 6-pin to 4-pin, part #172393 (0.84 m), DN 33329 -- only applicable to 16plus V2
to SBE 5M, 5T, or 5P (Y-cable to pump and data I/O, Standard connectors), part #17797, DN 31551 -- only applicable to 16plus V2
to SBE 5M, 5T, or 5P (Y-cable to pump and data I/O, optional Wet-pluggable connectors ), part #172220, DN 32896 -- only applicable to 16plus V2
to SBE 5M, 5T, or 5P (Standard connectors), part #17133 (1.12 m), DN 30565 -- not applicable to 16plus V2
to SBE 5M, 5T, or 5P (optional Wet-pluggable connectors), part #171503 (1.12 m), DN 32499 -- not applicable to 16plus V2
to SBE 43 (Standard connectors), part #172447 (1.1 m), DN 32496
to SBE 43 (optional Wet-pluggable connectors), part #172448 (1.1 m), DN 32654
to SBE 63 (Standard connectors), part #17088 (1.1 m), DN 30567
to SBE 63 (optional Wet-pluggable connectors), part #171792 (1.1 m), DN 32810
to Biospherical QSP-200PD (from 16plus Standard connector), part #171536 (1.5 m), DN 32536 -- not applicable to 16plus V2
to Biospherical QSP-2200PD (from 16plus Standard connector), part #171693 (1.5 m), DN 32693 -- not applicable to 16plus V2
to Biospherical QSP-200L or QSP-2300L (from 16plus/16plus V2 Standard connector), part #17610 (2 m), DN 30701
to Chelsea AquaTracka or AlphaTracka (from 16plus/16plus V2 Standard connector), part #17602 (1.2 m), DN 31253
to D&A OBS-3 (from 16plus/16plus V2 Standard connector), part #17361 (0.76 m), DN 30954
to D&A OBS-3+ (from 16plus/16plus V2 Standard connector), High & Low range, part #172130 (1 m), DN 33080
to D&A OBS-3+ (from 16plus/16plus V2 optional Wet-pluggable connector), High & Low range, part #172131 (1 m), DN 33081
to D&A OBS-3+ (from 16plus/16plus V2 Standard connector), Low range (1X), part #172109 (1 m), DN 33058
to D&A OBS-3+ (from 16plus/16plus V2 optional Wet-pluggable connector), Low range (1X), part #172111 (1 m), DN 33060
to D&A OBS-3+ (from 16plus/16plus V2 Standard connector), High range (4X), part #172110 (1 m), DN 33059
to D&A OBS-3+ (from 16plus/16plus V2 optional Wet-pluggable connector), High range (4X), part #172112 (1 m), DN 33061
to Li-Cor LI-192SA/193-SA (from 16plus/16plus V2 Standard connector), part #171559 (1.5 m), DN 32562
to Seapoint fluorometer or turbidity meter (1X) (from 16plus/16plus V2 Standard connector), part #171099 (1.1 m), DN 32073
to Seapoint fluorometer or turbidity meter (3X/5X) (from 16plus/16plus V2 Standard connector), part #171147 (1.1 m), DN 32101
to Seapoint fluorometer or turbidity meter (10X/20X) (from 16plus/16plus V2 Standard connector), part #172221 (1.1 m), DN 31933
to Seapoint fluorometer or turbidity meter (30X/100X) (from 16plus/16plus V2 Standard connector), part #171845 (1.1 m), DN 31924
to Turner Cyclops-7 (1X) (from 16plus/16plus V2 Standard connector), part #171908 (1.1 m), DN 32910
to Turner Cyclops-7 (10X) (from 16plus/16plus V2 Standard connector), part #171907 (1.1 m), DN 32909
to Turner Cyclops-7 (100X) (from 16plus/16plus V2 Standard connector), part #171909 (1.1 m), DN 32911
to Turner SCUFA (from 16plus/16plus V2 Standard connector), part #171418 (1.1 m), DN 32417
to WET Labs C-Star or WETStar with old-style 4-pin connector (from 16plus/16plus V2 Standard connector), part #17876 (1.1 m), DN 31725
to WET Labs ECO-AFL, ECO-FL, C-Star, or WETStar with new-style 6-pin connector (from 16plus/16plus V2 Standard connector), part #171953 (1.1 m), DN 32491
to WET Labs ECO-AFL, ECO-FL, C-Star, or WETStar with new-style 6-pin connector (from 16plus/16plus V2 Wet-pluggable connector), part #172437 (1.1 m), DN 32853
to WET Labs ECO-FL-NTUS or ECO-FL-NTU(RT) (from 16plus/16plus V2 Standard connector), part #171869 (1.1 m), DN 32812
to WET Labs ECO-FL-NTUS or ECO-FL-NTU(RT) (from 16plus/16plus V2 Wet-pluggable connector), part #172285 (1.1 m), DN 32846
SBE 17plus Searam Memory & Carousel Auto Fire Module (for SBE 9plus)to computer COM port from internal RS-232 connector for fast upload (digital firmware version > 2.2), part #801880, DN 33447
to computer COM port (from Surface Inductive Modem), part #171887
(replaces part #801373, DN 32431)to computer COM port (from Inductive Modem Module), part #801583 (0.25 m), DN 33049
to SBE 5M, 5T, or 5P (Standard connectors), part #17133 (1.12 m), DN 30565
to SBE 5M, 5T, or 5P (optional Wet-pluggable connectors), part #171503 (1.12 m), DN 32499
to SBE 43 (Standard connectors), part #172447 (1.1 m), DN 32496
to SBE 43 (optional Wet-pluggable connectors), part #172448 (1.1 m), DN 32654
to Biospherical QSP-200PD (from 16plus-IM Standard connector), part #171536 (1.5 m), DN 32536 -- not applicable to 16plus-IM V2
to Biospherical QSP-2200PD (from 16plus-IM Standard connector), part #171693 (1.5 m), DN 32693 -- not applicable to 16plus-IM V2
to Biospherical QSP-200L or QSP-2300L (from 16plus-IM/16plus-IM V2 Standard connector), part #17610 (2 m), DN 30701
to Chelsea AquaTracka or AlphaTracka (from 16plus-IM/16plus-IM V2 Standard connector), part #17602 (1.2 m), DN 31253
to D&A OBS-3 (from 16plus-IM/16plus-IM V2 Standard connector), part #17361 (0.76 m), DN 30954
to D&A OBS-3+ (from 16plus-IM/16plus-IM V2 Standard connector), High & Low range, part #172130 (1 m), DN 33080
to D&A OBS-3+ (from optional 16plus-IM/16plus-IM V2 Wet-pluggable connector), High & Low range, part #172131 (1 m), DN 33081
to D&A OBS-3+ (from 16plus-IM/16plus-IM V2 Standard connector), Low range (1X), part #172109 (1 m), DN 33058
to D&A OBS-3+ (from optional 16plus-IM/16plus-IM V2 Wet-pluggable connector), Low range (1X), part #172111 (1 m), DN 33060
to D&A OBS-3+ (from 16plus-IM/16plus-IM V2 Standard connector), High range (4X), part #172110 (1 m), DN 33059
to D&A OBS-3+ (from optional 16plus-IM/16plus-IM V2 Wet-pluggable connector), High range (4X), part #172112 (1 m), DN 33061
to Li-Cor LI-192SA/193-SA (from 16plus-IM/16plus-IM V2 Standard connector), part #171559 (1.5 m), DN 32562
to Seapoint fluorometer or turbidity meter (1X) (from 16plus-IM/16plus-IM V2 Standard connector), part #171099 (1.1 m), DN 32073
to Seapoint fluorometer or turbidity meter (3X/5X) (from 16plus-IM/16plus-IM V2 Standard connector), part #171147 (1.1 m), DN 32101
to Seapoint fluorometer or turbidity meter (10X/20X) (from 16plus-IM/16plus-IM V2 Standard connector), part #172221 (1.1 m), DN 31933
to Seapoint fluorometer or turbidity meter (30X/100X) (from 16plus-IM/16plus-IM V2 Standard connector), part #171845 (1.1 m), DN 31924
to Turner Cyclops-7 (1X) (from 16plus-IM/16plus-IM V2 Standard connector), part #171908 (1.1 m), DN 32910
to Turner Cyclops-7 (10X) (from 16plus-IM/16plus-IM V2 Standard connector), part #171907 (1.1 m), DN 32909
to Turner Cyclops-7 (100X) (from 16plus-IM/16plus-IM V2 Standard connector), part #171909 (1.1 m), DN 32911
to Turner SCUFA (from 16plus-IM/16plus-IM V2 Standard connector), part #171418 (1.1 m), DN 32417
to WET Labs C-Star or WETStar with old-style 4-pin connector (from 16plus-IM/16plus-IM V2 Standard connector), part #17876 (1.1 m), DN 31725
to WET Labs ECO-AFL, ECO-FL, C-Star, or WETStar with new-style 6-pin connector (from 16plus-IM/16plus-IM V2 Standard connector), part #171953 (1.1 m), DN 32491
to WET Labs ECO-AFL, ECO-FL, C-Star, or WETStar with new-style 6-pin connector (from 16plus-IM/16plus-IM V2 Wet-pluggable connector), part #172437 (1.1 m), DN 32853
to WET Labs ECO-FL-NTUS or ECO-FL-NTU(RT) (from 16plus-IM/16plus-IM V2 Standard connector), part #171869 (1.1 m), DN 32812
to WET Labs ECO-FL-NTUS or ECO-FL-NTU(RT) (from 16plus-IM/16plus-IM V2 Wet-pluggable connector), part #172285 (1.1 m), DN 32846
to computer COM port (from Standard connector),SBE 19plus V2 and 19plus (no longer in production) SeaCAT Profiler CTD
part #801380 (20 m shielded cable), DN 31222
part #801225 (2.4 m cable for bench use), DN 32421to computer COM port (from optional Wet-pluggable connector),
part #801421 (20 m shielded cable), DN 32789
part #801374 (2.4 m cable for bench use), DN 32715to SBE 9plus (Standard connectors), part #17132 (0.33 m), DN 30568
to SBE 9plus (optional Wet-pluggable connectors), part #171796 (0.33 m), DN 32758to SBE 32 (Standard connectors), part #17198 (2 m), DN 30568
to SBE 32 (optional Wet-pluggable connectors), part #171741 (2 m), DN 32758to AC power supply from NiMH Battery Charger (U.S. Standard), part #17015
to NiMH battery pack from NiMH Battery Charger, part #801509, DN 32935
SBE 21 SeaCAT Thermosalinographto computer COM port (from Standard connector), part #801225 (2.4 m), DN 32421
Note: For 19plus V2, 801225 connects to 4-pin end of Y-cable 17709.to computer COM port (from optional Wet-pluggable connector), part #801374 (2.4 m), DN 32715
Note: For 16plus V2, 801374 connects to 4-pin end of Y-cable 171883.to computer COM port, load-bearing cable (from Standard connector), part # varies with length, DN 32284 (also see Application Note 59)
Note: For 19plus V2, load-bearing cable connects to 4-pin end of Y-cable 17709.to computer COM port, load-bearing cable (from optional Wet-pluggable connector), part # varies with length, DN 32643 (also see Application Note 59)
Note: For 19plus V2, load-bearing cable connects to 4-pin end of Y-cable 171883.to SBE 5M, 5T, or 5P (Y-cable to pump and data I/O, Standard connectors), part #17709, DN 31551 -- only applicable to 19plus V2
to SBE 5M, 5T, or 5P (Y-cable to pump and data I/O, optional Wet-pluggable connectors), part #171883, DN 32896 -- only applicable to 19plus V2
to SBE 5M, 5T, or 5P (Standard connectors), part #17080 (0.38 m), DN 30565 -- not applicable to 19plus V2
to SBE 5M, 5T, or 5P (optional Wet-pluggable connectors), part #171502 (0.38 m), DN 32499 -- not applicable to 19plus V2
to SBE 18 (Standard connectors), part #17595 (1.1 m), DN 30918
to SBE 27 (Standard connectors), part #171704 (1.1 m), DN 31749
to SBE 32 (Standard connectors), part #17292 (2 m), DN 30567
to SBE 32 (optional Wet-pluggable connectors), part #171912 (2 m), DN 32810
to SBE 43 (Standard connectors), part #172447 (1.1 m), DN 32496
to SBE 43 (optional Wet-pluggable connectors), part #172448 (1.1 m), DN 32654
to SBE 63 (Standard connectors), part #17088 (1.1 m), DN 30567
to SBE 63 (optional Wet-pluggable connectors), part #171792 (1.1 m), DN 32810
to Auto Fire Module (AFM) (Standard connectors), part #17821 (1.2 m) or 17884 (1.8 m), DN 31670
to Auto Fire Module (AFM) (optional Wet-pluggable connectors), part #171846 (1.8 m), DN 32859
to Power & Data Interface Module (PDIM), (Standard connectors), part #17088 (1.1 m), DN 30567
to Power & Data Interface Module (PDIM), (optional Wet-pluggable connectors), part #171792 (1.1 m), DN 32810
to Benthos/Datasonics PSA-916 (from 19plus/19plus V2 Standard connector), part #171130 (1.8 m), DN 32075
to Biospherical QSP-200PD (from 19plus Standard connector), part #171536 (1.5 m), DN 32536 -- not applicable to 19plus V2
to Biospherical QSP-2200PD (from 19plus Standard connector), part #171693 (1.5 m), DN 32693 -- not applicable to 19plus V2
to Biospherical QSP-200L or QSP-2300L (from 19plus/19plus V2 Standard connector), part #17610 (2 m), DN 30701
to Chelsea AquaTracka or AlphaTracka (from 19plus/19plus V2 Standard connector), part #17602 (1.2 m), DN 31253
to D&A OBS-3 (from 19plus/19plus V2 Standard connector), part #17361 (0.76 m), DN 30954
to D&A OBS-3+ (from 19plus/19plus V2 Standard connector), High & Low range, part #172130 (1 m), DN 33080
to D&A OBS-3+ (from optional 19plus/19plus V2 Wet-pluggable connector), High & Low range, part #172131 (1 m), DN 33081
to D&A OBS-3+ (from 19plus/19plus V2 Standard connector), Low range (1X), part #172109 (1 m), DN 33058
to D&A OBS-3+ (from optional 19plus/19plus V2 Wet-pluggable connector), Low range (1X), part #172111 (1 m), DN 33060
to D&A OBS-3+ (from 19plus/19plus V2 Standard connector), High range (4X), part #172110 (1 m), DN 33059
to D&A OBS-3+ (from optional 19plus/19plus V2 Wet-pluggable connector), High range (4X), part #172112 (1 m), DN 33061
to Li-Cor LI-192SA/193-SA (from 19plus/19plus V2 Standard connector), part #171559 (1.5 m), DN 32562
to Satlantic SatPAR (from 19plus/19plus V2 Standard connector), part # 172215 (2 m), DN 32628
to Satlantic SatPAR (from 19plus/19plus V2 Wet-pluggable connector), part # 172214 (2 m), DN 32654
to Seapoint fluorometer or turbidity meter (1X) (from 19plus/19plus V2 Standard connector), part #171099 (1.1 m), DN 32073
to Seapoint fluorometer or turbidity meter (3X/5X) (from 19plus/19plus V2 Standard connector), part #171147 (1.1 m), DN 32101
to Seapoint fluorometer or turbidity meter (10X/20X) (from 19plus/19plus V2 Standard connector), part #172221 (1.1 m), DN 31933
to Seapoint fluorometer or turbidity meter (30X/100X) (from 19plus/19plus V2 Standard connector), part #171845 (1.1 m), DN 31924
to Turner Cyclops-7 (1X) (from 19plus/19plus V2 Standard connector), part #171908 (1.1 m), DN 32910
to Turner Cyclops-7 (10X) (from 19plus/19plus V2 Standard connector), part #171907 (1.1 m), DN 32909
to Turner Cyclops-7 (100X) (from 19plus/19plus V2 Standard connector), part #171909 (1.1 m), DN 32911
to Turner SCUFA (from 19plus/19plus V2 Standard connector), part #171418 (1.1 m), DN 32417
to WET Labs C-Star or WETStar with old-style 4-pin connector (from 19plus/19plus V2 Standard connector), part #17876 (1.1 m), DN 31725
to WET Labs ECO-AFL, ECO-FL, C-Star, or WETStar with new-style 6-pin connector (from 19plus/19plus V2 Standard connector), part #171953 (1.1 m), DN 32491
to WET Labs ECO-AFL, ECO-FL, C-Star, or WETStar with new-style 6-pin connector (from 19plus/19plus V2 Wet-pluggable connector), part #172437 (1.1 m), DN 32853
to WET Labs ECO-FL-NTUS or ECO-FL-NTU(RT) (from 19plus/19plus V2 Standard connector), part #171869 (1.1 m), DN 32812
to WET Labs ECO-FL-NTUS or ECO-FL-NTU(RT) (from 19plus/19plus V2 Wet-pluggable connector), part #172285 (1.1 m), DN 32846
to AC power supply from optional NiMH Battery Charger (U.S. Standard), part #17015
to NiMH battery pack (from optional NiMH Battery Charger), part #801509, DN 32935
to SBE 3, part #17360 (10 m), DN 30764SBE 25plus and 25 (no longer in production) Sealogger CTDto SBE 38, part #171012 (10 m), DN 31311
to ground, part #17725 (4.6 m), DN 32280
to 90488, 90158.1, or 90204 SeaCAT/Sealogger RS-232 and Navigation Interface Box, part #80437 (2.5 m) or #80438 (10 m), DN 31063
to computer COM port (from 90488, 90158.1, or 90204 Interface Box), part #171887
(replaces part #801373, DN 32431)to NMEA simulation computer COM port (from 90488, 90158.1, or 90204 Interface Box NMEA Input), part #801424 (1.8 m), DN 32787
to AC power supply from 90488, 90158.1, or 90204 Interface Box (U.S. Standard), part #17015
Note: Note: PN 90488 is current AC-powered Interface Box; PN 90158.1 is an older AC-powered Interface Box, and PN 90204 is current DC-powered Interface Box.
to computer COM port (from Y-cable, Standard connectors),SBE 26plus and SBE 26 (no longer in production) Seagauge Wave & Tide Recorder
part #801380 (20 m shielded cable), DN 31222
part #801225 (2.4 m cable for bench use), DN 32421to computer COM port (from Y-cable, Wet-pluggable connectors),
part #801421 (20 m shielded cable), DN 32789
part #801374 (2.4 m cable for bench use), DN 32715to computer COM port, load-bearing cable (from Y-cable, Standard connectors), part # varies with length, DN 32284 (also see Application Note 59)
to computer COM port, load-bearing cable (from Y-cable, Wet-pluggable connectors), part # varies with length, DN 32643 (also see Application Note 59)
to SBE 3 or SBE 4 (Standard connectors), part #17086 (0.64 m), DN 30566
to SBE 3 or SBE 4 (optional Wet-pluggable connectors), part #171669 (0.76 m), DN 32671
to SBE 5T or 5P (Y-cable to pump and data I/O, Standard connectors), part #17709, DN 31551
to SBE 5T or 5P (Y-cable to pump and data I/O, optional Wet-pluggable connectors), part #171883, DN 32896
to SBE 29 (Standard connectors), part #17168 (1.1 m), DN 30568 -- only applicable to SBE 25
to SBE 29 (optional Wet-pluggable connectors), part #171798 (1.0 m), DN 32758 -- only applicable to SBE 25
to SBE 18 (Standard connectors), part #17595 (1.1 m), DN 30918
to SBE 27 (Standard connectors), part #171704 (1.1 m), DN 31749
to SBE 32 (Standard connectors), part #17292 (2 m), DN 30567
to SBE 32 (optional Wet-pluggable connectors), part #171912 (2 m), DN 32810
to SBE 43 (Standard connectors), part #172447 (1.1 m), DN 32496
to SBE 43 (optional Wet-pluggable connectors), part #172448 (1.1 m), DN 32654
to Power & Data Interface Module (PDIM) (Standard connectors), part #17088 (1.1 m), DN 30567
to Power & Data Interface Module (PDIM) (optional Wet-pluggable connectors), part #171792 (1.1 m), DN 32810
to Auto Fire Module (AFM) (Standard connectors), part #17821 (1.2 m) or 17884 (1.8 m), DN 31670
to Auto Fire Module (AFM) (optional Wet-pluggable connectors), part #171846 (1.8 m), DN 32859
to Benthos/Datasonics PSA-916 (from 25/25plus Standard connector), part #171130 (1.8 m), DN 32075
to Biospherical QSP-200PD (from 25/25plus Standard connector), part #17342 (1.1 m), DN 30922
to Biospherical QSP-2200 (from 25/25plus Standard connector), part #171640 (1.5 m), DN 32648
to Biospherical QSP-200L or QSP-2300L (from 25/25plus Standard connector), part #17610 (2 m), DN 30701
to Chelsea AquaTracka or AlphaTracka (from 25/25plus Standard connector), part #17602 (1.2 m), DN 31253
to D&A OBS-3 (from 25/25plus Standard connector), part #17361 (0.76 m), DN 30954
to D&A OBS-3+ (from 25/25plus Standard connector), High & Low range, part #172130 (1 m), DN 33080
to D&A OBS-3+ (from 25/25plus optional Wet-pluggable connector), High & Low range, part #172131 (1 m), DN 33081
to D&A OBS-3+ (from 25/25plus Standard connector), Low range (1X), part #172109 (1 m), DN 33058
to D&A OBS-3+ (from 25/25plus optional Wet-pluggable connector), Low range (1X), part #172111 (1 m), DN 33060
to D&A OBS-3+ (from 25/25plus Standard connector), High range (4X), part #172110 (1 m), DN 33059
to D&A OBS-3+ (from 25/25plus optional Wet-pluggable connector), High range (4X), part #172112 (1 m), DN 33061
to Li-Cor 192-SA/193-SA (from 25/25plus Standard connector), part #17343 (1.1 m), DN 30923
to Satlantic SatPAR (from 25/25plus Standard connector), part # 172215 (2 m), DN 32628
to Satlantic SatPAR (from 25/25plus Wet-pluggable connector), part # 172214 (2 m), DN 32654
to Seapoint fluorometer or turbidity meter (1X) (from 25/25plus Standard connector), part #171099 (1.1 m), DN 32073
to Seapoint fluorometer or turbidity meter (3X/5X) (from 25/25plus Standard connector), part #171147 (1.1 m), DN 32101
to Seapoint fluorometer or turbidity meter (10X/20X) (from 25/25plus Standard connector), part #172221 (1.1 m), DN 31933
to Seapoint fluorometer or turbidity meter (30X/100X) (from 25/25plus Standard connector), part #171845 (1.1 m), DN 31924
to Turner Cyclops-7 (1X) (from 25/25plus Standard connector), part #171908 (1.1 m), DN 32910
to Turner Cyclops-7 (10X) (from 25/25plus Standard connector), part #171907 (1.1 m), DN 32909
to Turner Cyclops-7 (100X) (from 25/25plus Standard connector), part #171909 (1.1 m), DN 32911
to Turner SCUFA (from 25/25plus Standard connector), part #171418 (1.1 m), DN 32417
to WET Labs C-Star or WETStar with old-style 4-pin connector (from 25/25plus Standard connector), part #17876 (1.1 m), DN 31725
to WET Labs ECO-AFL, ECO-FL, C-Star, or WETStar with new-style 6-pin connector (from 25/25plus Standard connector), part #171953 (1.1 m), DN 32491
to WET Labs ECO-AFL, ECO-FL, C-Star, or WETStar with new-style 6-pin connector (from 25/25plus V2 Wet-pluggable connector), part #172437 (1.1 m), DN 32853
to WET Labs ECO-FL-NTUS or ECO-FL-NTU(RT) (from 25/25plus Standard connector), part #171869 (1.1 m), DN 32812
to WET Labs ECO-FL-NTUS or ECO-FL-NTU(RT) (from 25/25plus Wet-pluggable connector), part #172285 (1.1 m), DN 32846
to AC power supply from optional NiMH Battery Charger (U.S. Standard), part #17015 -- only applicable to SBE 25
to NiMH battery pack (from optional NiMH Battery Charger), part #801509, DN 32935 -- only applicable to SBE 25
to computer COM port (from Standard 4-pin RS-232 connector), part #801225 (2.4 m), DN 32421to computer COM port (from 4-pin RS-232 connector, optional Wet-pluggable connector), part #801374 (2.4 m), DN 32715
to computer COM port (from optional 6-pin RS-422/RS-485 connector, Standard), part #801584 (2.4 m), DN 33051
Note: RS-422/RS-485 interface available only for SBE 26plus.to computer COM port (from optional 6-pin RS-422/RS-485 connector, Wet-pluggable), part #802124 (2.4 m), DN 33661
Note: RS-422/RS-485 interface available only for SBE 26plus.to SBE 4 (Standard connectors), part #17695 (0.28 m), DN 30566
to SBE 4 (optional Wet-pluggable connectors), part #171752 (0.28 m), DN 32671
SBE 32 Carousel Water Samplerto computer COM port, part #171886 (3 m)
to AC power supply (U.S. Standard), part #17015
to SBE 9plus or 17plus (Standard connectors), part #17198 (2 m), DN 30568SBE 33 Carousel Deck Unitto SBE 9plus or 17plus (optional Wet-pluggable connectors), part #171741 (2 m), DN 32758
to SBE 19plus, 19plus V2, 25, or 25plus (Standard connectors), part #17292 (2 m), DN 30567
to SBE 19plus, 19plus V2, 25, or 25plus (optional Wet-pluggable connectors), part #171912 (2 m), DN 32810
to SBE 33 (from SBE 32 Standard connector) (test cable), part #80915 (10 m), DN 31314
to SBE 33 (from SBE 32 optional Wet-pluggable connector) (test cable), part #801363 (2.4 m), DN 32695
to SBE 35 or 35RT (Standard connectors) (when SBE 32 used with SBE 911plus or SBE 32 used with AFM), part #171220 Y-cable (SBE 9plus/35/32 or AFM/35/32), DN 32208
to SBE 35 or 35RT (optional Wet-pluggable connectors) (when SBE 32 used with SBE 911plus or SBE 32 used with AFM), part #171995 Y-cable (SBE 9plus/35/32 or AFM/35/32), DN 32963
to SBE 35 or 35RT (Standard connectors) (when SBE 32 used with SBE 33 Deck Unit), part #171221 (2.4 m), DN 32209
to SBE 35 or 35RT (optional Wet-pluggable connectors) (when SBE 32 used with SBE 33 Deck Unit), part #171996 (2.4 m), DN 32964
to Auto Fire Module (Standard connectors), part #17168 (1.1 m) or 17198 (2 m), DN 30568
to Auto Fire Module (optional Wet-pluggable connectors), part #171798 (1.0 m) or #171741 (2 m), DN 32758
to Auto Fire Module and SBE 50 (Standard connectors), part #171730, DN 32740
to Auto Fire Module and SBE 50 (optional Wet-pluggable connectors), part #171991, DN 32959
sea cable extension for SBE 32 with optional serial interface (Standard connectors), part #17120 (2 m), DN 30588
sea cable extension for SBE 32 with optional serial interface (Wet-pluggable connectors), part #171743 (2 m), DN 32763
to computer COM port (from SBE 33 Serial Data or Carousel Data), part #171886 (3 m) -- SBE 33 with firmware < 3.0 (25-pin connector on SBE 33)
to computer COM port (from SBE 33 Serial Data or Carousel Data), part #171887 (3 m) -- SBE 33 with firmware > 3.0 (9-pin connector on SBE 33)to AC power supply (U.S. Standard), part #17015
to SBE 32 or 55 Water Sampler (with Standard connectors) (test cable) (from SBE 33 Sea Cable), part #80915 (10 m), DN 31314
to SBE 32 or 55 Water Sampler (with optional Wet-pluggable connectors) (test cable) (from SBE 33 Sea Cable), part #801363 (2.4 m), DN 32695
to slip ring, part # varies depending on length (from SBE 33 Sea Cable), DN 31371
to NMEA simulation computer COM port (from SBE 33 NMEA Input), part #801422 (1.8 m), DN 32786
to Surface PAR QSR-2200 or QCR-2200 with Switchcraft connector (from SBE 33 PAR Input), part #801367 (15 m), DN 32704
to Surface PAR QSR-240 or QCR-240 with Bendix connector (from SBE 33 PAR Input), part #80665 (30 m), DN 31475
to Surface PAR QSR-240 or -2200 or QCR-240 or -2200 with Lemo connector (from SBE 33 PAR Input), part #801238 (30 m), DN 32434
SBE 35 Deep Ocean Standards Thermometer & SBE 35RT Digital Reversing Thermometer
SBE 36 CTD Deck Unitto Power Supply / Interface Box (from 35/35RT Standard connector), part #80555 (2.4 m), DN 31116
to Power Supply / Interface Box (from 35/35RT optional Wet-pluggable connector), part #801534 (2.4 m), DN 32962
to computer COM port (from Power Supply / Interface Box), part #171887 (3 m)
(replaces part #801373, DN 32431)to AC power supply from Power Supply / Interface Box (U.S. Standard), part #17015
to SBE 32 and SBE 9plus or 17plus V2 or AFM (Standard connectors), part #171220 Y-cable, DN 32208
to SBE 32 and SBE 9plus or 17plus V2 or AFM (optional Wet-pluggable connectors), part #171995 Y-cable, DN 32963
to SBE 32 (Standard connectors) (when SBE 32 used with SBE 33 Deck Unit), part #171221 (2.4 m), DN 32209
to SBE 32 (optional Wet-pluggable connectors) (when SBE 32 used with SBE 33 Deck Unit), part #171996 (2.4 m), DN 32964
SBE 37-SMP-ODO or 37-SMP-IDO MicroCAT C-T-DO (P optional) Recorderto computer COM port (from SBE 36 Serial Data), part #171886 (3 m) -- SBE 36 with firmware < 3.0 (25-pin connector on SBE 36)
to computer COM port (from SBE 36 Serial Data), part #171887 (3 m) -- SBE 36 with firmware > 3.0 (9-pin connector on SBE 36)
to AC power supply (U.S. Standard), part #17015
to PDIM (test cable), part #80915 (10 m) (from SBE 36 Sea Cable), DN 31314to PDIM (with optional Wet-pluggable connectors) (test cable) (from SBE 36 Sea Cable), part #801363 (2.4 m), DN 32695
to slip ring, part # varies depending on length (from SBE 36 Sea Cable), DN 31371
to NMEA simulation computer COM port (from SBE 36 NMEA Input), part #801422 (1.8 m), DN 32786
to Surface PAR QSR-2200 or QCR-2200 with Switchcraft connector (from SBE 36 PAR Input), part #801367 (15 m), DN 32704
to Surface PAR QSR-240 or QCR-240 with Bendix connector (from SBE 36 PAR Input), part #80665 (30 m), DN 31475
to Surface PAR QSR-240 or -2200 or QCR-240 or -2200 with Lemo connector (from SBE 36 PAR Input), part #801238 (30 m), DN 32434
SBE 37-SMP MicroCAT C-T (P optional) RecorderRS-232 or RS-485 versions
to computer COM port with power leads (from Standard connector), part #801385 (2.4 m), DN 32277
to computer COM port with 9V connector (from Standard connector), part #801376 (2.4 m), DN 32604
to computer COM port with power leads (from optional Wet-pluggable connector), part #801206 (2.4 m), DN 32366
to computer COM port with 9V connector (from optional Wet-pluggable connector), part #801263 (2.4 m), DN 32490
SDI-12 version
to computer COM port with power leads and leads to SDI-12 (from Wet-pluggable connector), part #802220 (2.4 m), DN 33733
SBE 37-SM MicroCAT C-T (P optional) RecorderRS-232 or RS-485 versions
(Note: In 2008, a 4-pin bulkhead connector became standard for all 37-SMPs. Previously, a 3-pin connector was standard and a 4-pin connector was optional.)
to computer COM port with power leads (from 4-pin connector for external power or RS-485), part #801385 (2.4 m), DN 32277
to computer COM port with 9V connector (from 4-pin connector for external power or RS-485), part #801376 (2.4 m), DN 32604
to computer COM port with power leads (from 4-pin Wet-pluggable connector for external power or RS-485), part #801206 (2.4 m), DN 32366
to computer COM port with 9V connector (from 4-pin Wet-pluggable connector for external power or RS-485), part #801263 (2.4 m), DN 32490
to computer COM port (from 3-pin connector), part #801412 (2.4 m), DN 32778
to computer COM port (from 3-pin Wet-pluggable connector), part #801366 (2.4 m), DN 32702
SDI-12 version
to computer COM port with power leads and leads to SDI-12 (from Wet-pluggable connector), part #802220 (2.4 m), DN 33733
(Note: In 2008, a 4-pin bulkhead connector became standard for all 37-SMs. Previously, a 3-pin connector was standard and a 4-pin connector was optional.)SBE 37-SIP-IDO MicroCAT C-T-DO (P optional) Sensorto computer COM port with power leads (from 4-pin connector for external power or RS-485), part #801385 (2.4 m), DN 32277
to computer COM port with 9V connector (from 4-pin connector for external power or RS-485), part #801376 (2.4 m), DN 32604
to computer COM port with power leads (from 4-pin Wet-pluggable connector), part #801206 (2.4 m), DN 32366
to computer COM port with 9V connector (from 4-pin Wet-pluggable connector), part #801263 (2.4 m), DN 32490
to computer COM port (from 3-pin connector), part #801412 (2.4 m), DN 32778
to computer COM port (from 3-pin Wet-pluggable connector), part #801366 (2.4 m), DN 32702
For 37-SM with Pump (no longer in production):
to computer COM port (from optional 4-pin connector for pump power), part #801225 (2.4 m), DN 32421
to computer COM port (from optional 4-pin Wet-pluggable connector for pump power), part #801374 (2.4 m), DN 32715
to SBE 5M, part #171335 (0.41 m), DN 32333
to SBE 5M (optional Wet-pluggable connectors), part #171682 (0.41 m), DN 32686
to computer COM port with power leads (from Standard connector), part #801385 (2.4 m), DN 32277SBE 37-SIP MicroCAT C-T (P optional) Sensorto computer COM port with 9V connector (from Standard connector), part #801376 (2.4 m), DN 32604
to computer COM port with power leads (from optional Wet-pluggable connector), part #801206 (2.4 m), DN 32366
to computer COM port with 9V connector (from optional Wet-pluggable connector), part #801263 (2.4 m), DN 32490
to computer COM port with power leads (from Standard connector), shielded, part #801378 (20 m), DN 32720
to computer COM port with power leads (from Standard connector), part #801385 (2.4 m), DN 32277to computer COM port with 9V connector (from Standard connector), part #801376 (2.4 m), DN 32604
to computer COM port with power leads (from optional Wet-pluggable connector), part #801206 (2.4 m), DN 32366
to computer COM port with 9V connector (from optional Wet-pluggable connector), part #801263 (2.4 m), DN 32490
to computer COM port with power leads (from Standard connector), shielded, part #801378 (20 m), DN 32720
SBE 37-SI MicroCAT C-T (P optional) Sensor
to computer COM port with power leads (from Standard connector), part #801385 (2.4 m), DN 32277SBE 37-IMP-ODO or 37-IMP-IDO MicroCAT C-T-DO (P optional) Recorderto computer COM port with 9V connector (from Standard connector), part #801376 (2.4 m), DN 32604
to computer COM port with power leads (from optional Wet-pluggable connector), part #801206 (2.4 m), DN 32366
to computer COM port with 9V connector (from optional Wet-pluggable connector), part #801263 (2.4 m), DN 32490
SBE 37-IMP MicroCAT C-T (P optional) Recorderto computer COM port from internal RS-232 connector for fast upload (digital firmware version > 3.0), part #801836, DN 33406
to computer COM port (from Surface Inductive Modem), part #171887 (3 m)
(replaces part #801373, DN 32431)to computer COM port (from Inductive Modem Module), part #801583 (0.25 m), DN 33049
SBE 37-IM MicroCAT C-T (P optional) Recorderto computer COM port from internal RS-232 connector for fast upload (digital firmware version > 3.0), part #801836, DN 33406
to computer COM port (from Surface Inductive Modem), part #171887 (3 m)
(replaces part #801373, DN 32431)to computer COM port (from Inductive Modem Module), part #801583 (0.25 m), DN 33049
SBE 38 Digital Oceanographic Thermometerto computer COM port from internal RS-232 connector for fast upload (digital firmware version > 3.0), part #801836, DN 33406
to computer COM port (from Surface Inductive Modem), part #171887 (3 m)
(replaces part #801373, DN 32431)to computer COM port (from Inductive Modem Module), part #801583 (0.25 m), DN 33049
to computer COM port with 9V connector (from Standard connector), part #801376 (2.4 m), DN 32604
to computer COM port with power leads (from Standard connector), part #801385 (2.4 m), DN 32277
pigtail (from Standard connector), part #17031 (2.4 m), DN 30581
to computer COM port with 9V connector (from optional Wet-pluggable connector), part #801263 (2.4 m), DN 32490
to computer COM port with power leads (from optional Wet-pluggable connector), part #801206 (2.4 m), DN 32366
pigtail (from optional Wet-pluggable connector), part #171368 (2.4 m), DN 32363
SBE 39 Temperature (P optional) Recorder
to computer COM port (from internal Molex connector), part #801413 (2.4 m), DN 32779to computer COM port with 9V connector (from optional external connector), part #801376 (2.4 m), DN 32604
to computer COM port with power leads (from optional external connector), part #801385 (2.4 m), DN 32277
to computer COM port with 9V connector (from optional external, Wet-pluggable connector), part #801263 (2.4 m), DN 32490
to computer COM port with power leads (from optional external, Wet-pluggable connector), part #801206 (2.4 m), DN 32366
SBE 39-IM Temperature (P optional) Recorder
SBE 44 Underwater Inductive Modemto computer COM port (from 39-IM internal RS-232 connector for fast data upload), part #801579 (1.8 m), DN 33041
to computer COM port (from Surface Inductive Modem), part #171887 (3 m)
(replaces part #801373, DN 32431)to computer COM port (from Inductive Modem Module), part #801583 (0.25 m), DN 33049
to computer COM port (from Surface Inductive Modem), part #171887 (3 m)SBE 45 MicroTSG Thermosalinograph
(replaces part #801373, DN 32431)to computer COM port (from Inductive Modem Module), part #801583 (0.25 m), DN 33049
to computer COM port (from SBE 44 Standard connector for serial instrument, for testing), part #801434 (2.4 m), DN 32806
to computer COM port (from SBE 44 Wet-pluggable connector for serial instrument, for testing), part #801450 (2.4 m), DN 32832
to computer COM port, part #801392 (2.4 m), DN 32756SBE 46 LCD Data Display (no longer in production)to optional PN 90402 - SBE 45 Interface Box, part #801216 (2.4 m), DN 32397
to computer COM port (from optional PN 90402 - SBE 45 Interface Box PC), part #171887 (3 m)
(replaces part #801373, DN 32431)to SBE 38 (from optional PN 90402 - SBE 45 Interface Box SBE 38), part #80437 (2.4 m) or 80438 (10 m), DN 31063
to NMEA simulation computer COM port (from optional PN 90402 - SBE 45 Interface Box NMEA), part #801422 (1.8 m), DN 32786
to AC power supply from optional PN 90402 - SBE 45 Interface Box (U.S. Standard), part #17015
to computer COM port (from SBE 46 PC/SBE 11), part #171887 (3 m)SBE 48 Hull Temperature Sensor
(replaces part #801373, DN 32431)to SBE 37 (-SM, -SMP, or -SI), 38, 39, or 50 4-pin connector (from SBE 46 Sensor), part #80437 (2.4 m), DN 31063
to SBE 45 (from SBE 46 Sensor), part #801216 (2.4 m), DN 32397
to SBE 11plus Remote Out (from SBE 46 PC/SBE 11), part #801215 (2.4 m), DN 32396
to AC power supply (U.S. Standard), part #17015
to DC power supply, part #801217 (1.1 m), DN 32398
to computer COM port, part # 801431 (2.4 m), DN 32805to computer COM port, part # 801432 (10 m), DN 32805
to computer COM port with power leads (from Standard connector), part #801385 (2.4 m), DN 32277SBE 50 Digital Oceanographic Pressure Sensorto computer COM port with 9V connector (from Standard connector), part #801376 (2.4 m), DN 32604
pigtail (from Standard connector), part #17031 (2.4 m), DN 30581
to computer COM port with power leads (from optional Wet-pluggable connector), part #801206 (2.4 m), DN 32366
to computer COM port with 9V connector (from optional Wet-pluggable connector), part #801263 (2.4 m), DN 32490
pigtail (from optional Wet-pluggable connector), part #171368 (2.4 m), DN 32363
to Power & Data Interface Module (PDIM), Standard connectors, part #17088 (1.1 m), DN 30567
to Power & Data Interface Module (PDIM), optional Wet-pluggable connectors, part #171792 (1.1 m), DN 32810
to computer COM port with power leads (from Standard 4-pin connector), part #801385 (2.4 m), DN 32277SBE 52-MP Moored Profiler CTD & Optional DO Sensorto computer COM port with 9V connector (from Standard 4-pin connector), part #801376 (2.4 m), DN 32604
pigtail (from Standard 4-pin connector), part #17031 (2.4 m), DN 30581
to computer COM port with power leads (from optional 6-pin connector), part #801386 (2.4 m), DN 32737
pigtail (from optional 6-pin connector), part #17032 (2.4 m), DN 30582
to computer COM port with power leads (from optional Wet-pluggable 4-pin connector), part #801206 (2.4 m), DN 32366
to computer COM port with 9V connector (from optional Wet-pluggable 4-pin connector), part #801263 (2.4 m), DN 32490
pigtail (from optional Wet-pluggable 4-pin connector), part #171368 (2.4 m), DN 32363
to computer COM port with power leads (from optional Wet-pluggable 6-pin connector), part #801387 (2.4 m), DN 32738
pigtail (from optional Wet-pluggable 6-pin connector), part #171513 (2.4 m), DN 32515
pigtail (from Standard connector), part #17031 (2.4 m), DN 30581SBE 53 BPR Bottom Pressure Recorderto computer COM port with power leads (from Standard connector), part #801385 (2.4 m), DN 32277
pigtail (from optional Wet-pluggable connector), part #171368 (2.4 m), DN 32363
to computer COM port with power leads (from optional Wet-pluggable connector), part #801206 (2.4 m), DN 32366
to dissolved oxygen sensor, part #171558 (0.53 m), DN 32561
to computer COM port, part #801225 (2.4 m), DN 32421SBE 54 Tsunameter - Tsunami Pressure Sensorto computer COM port (from optional Wet-pluggable connector), part #801374 (2.4 m), DN 32715
to SBE 4, part #17695 (0.28 m), DN 30566
to SBE 4 (from optional Wet-pluggable connector), part #171752 (0.28 m), DN 32671
to computer COM port, part #801225 (2.4 m), DN 32421SBE 55 ECO Water Samplerto computer COM port (from optional Wet-pluggable connector), part #801374 (2.4 m), DN 32715
SBE 56 Temperature Loggerto latch assembly from Electronics Control Module (Standard connectors), part #17088 (1.1 m), DN 30567
to latch assembly from Electronics Control Module (optional Wet-pluggable connectors), part #171792 (1.1 m), DN 32810
data I/O cable extension (Standard connectors), 6-pin to 4-pin, part #172302 (0.76 m), DN 33233
data I/O cable extension (optional Wet-pluggable connectors), 6-pin to 4-pin, part #172303 (0.76 m), DN 33234
to computer COM port from data I/O cable extension (Standard connectors), part #801436 (20 m), DN 32808
to computer COM port from data I/O cable extension (optional Wet-pluggable connectors), part #801460 (20 m), DN 32861
to SBE 19, 19plus, 19plus V2, 25, 25plus, 49, or 50 (Standard connectors), part #172259 (1.2 m), DN 33191
to SBE 19, 19plus, 19plus V2, 25, 25plus, 49, or 50 (optional Wet-pluggable connectors), part #172260 (1.2 m), DN 33192
to SBE 33 (from SBE 55 with Standard connectors) (test cable), part #80915 (10 m), DN 31314
to SBE 33 (from SBE 55 with optional Wet-pluggable connectors) (test cable), part #801587 (10 m), DN 32695
sea cable extension (Standard connectors), part #17120 (2 m), DN 30588
sea cable extension (Wet-pluggable connectors), part #171743 (2 m), DN 32763
SeaCAT/Sealogger RS-232 and Navigation Interface Box for SBE 16, 16plus, 16plus V2, 19, 19plus, 19plus V2, 21, 25, or 25plus (PN 90488, 90545, 90158.1, or 90204)to computer USB port, part #172557 (1.8 m)
to CTD (Standard connector), part #80437 (2.5 m) or 80438 (10 m), DN 31063to CTD (Standard connector), load-bearing cable, part # varies with length, DN 32821
to computer COM port, part #171887 (3 m)
(replaces part #801373, DN 32431)to NMEA simulation computer COM port (from Interface Box NMEA Input), part #801424 (1.8 m), DN 32787
Notes:
- PN 90488 is current AC-powered Interface Box; PN 90158.1 is an older AC-powered Interface Box.
- PN 90545 is current DC-powered Interface Box; PN 90204 is an older DC-powered Interface Box.
SBE 45 Power, Navigation, and Remote Temperature Interface Box (PN 90402)
Carousel Auto Fire Module (AFM)to SBE 45, part #801216 (2.4 m), DN 32397
to computer COM port, part #171887 (3 m)
(replaces part #801373, DN 32431)to SBE 38 (from Interface Box SBE 38), part #80437 (2.4 m) or 80438 (10 m), DN 31063
to NMEA simulation computer COM port (from Interface Box NMEA), part #801422 (1.8 m), DN 32786
to computer COM port, part #801436 (20 m), DN 32808Power and Data Interface Module (PDIM)to computer COM port (from AFM with optional Wet-pluggable connectors), part #801460 (20 m), DN 32861
to SBE 19, 19plus, 19plus V2, 25, or 25plus part #17821 (1.2 m) or 17884 (1.8 m), DN 31670
to SBE 19, 19plus, 19plus V2, 25, or 25plus (optional Wet-pluggable connectors), part #171846 (1.8 m), DN 32859
to SBE 32, part #17168 (1.1 m) or 17198 (2 m), DN 30568
to SBE 32 (optional Wet-pluggable connectors), part #171798 (1 m) or #171741 (2 m), DN 32758
to SBE 32 and SBE 50 (Standard connectors), part #171730, DN 32740
to SBE 32 and SBE 50 (optional Wet-pluggable connectors), part #171991, DN 32959
to SBE 35 or 35RT (when SBE 32 used with AFM), part #171220 Y-cable (AFM/35/32), DN 32208
to SBE 35 or 35RT (optional Wet-pluggable connectors) (when SBE 32 used with AFM), part #171995 Y-cable (AFM/35/32), DN 32963
to SBE 36 (test cable), part #80915 (10 m), DN 31314Surface Inductive Modem (SIM)to SBE 36 (from PDIM with optional Wet-pluggable connectors) (test cable), part #801363 (2.4 m), DN 32695
to SBE 19, 19plus, 19plus V2, 25, or 25plus (Standard connectors), part #17088 (1.1 m), DN 30567
to SBE 19, 19plus, 19plus V2, 25, or 25plus (optional Wet-pluggable connectors), part #171792 (1.1 m), DN 32810
to computer COM port, part #171887 (3 m)Inductive Modem Module (IMM)
(replaces part #801373, DN 32431)
to computer COM port, part #801583 (0.25 m), DN 33049
Underwater Inductive Modem Module (UIMM)
Glider Payload CTD (GPCTD)to computer COM port with 9V connector, part #801263 (2.4 m), DN 32490
to computer COM port with power leads, part #801944 (2.5 m), DN 33511
to pump, part #172581 (0.5 m), DN 33474
to SBE 43F DO sensor, part #171558 (0.53 m), DN 32561
part #17027, 2-pin pigtail cable (RMG-2FS with lock sleeve), 0.5 m (DN 30579)
part #17028, 2-pin pigtail cable (RMG-2FS with lock sleeve), 2.4 m (DN 30579)
part #17029, 3-pin pigtail cable (RMG-3FS with lock sleeve), 0.5 m (DN 30580)
part #17030, 3-pin pigtail cable (RMG-3FS with lock sleeve), 2.4 m (DN 30580)
part #17031, 4-pin pigtail cable (RMG-4FS with lock sleeve), 2.4 m (DN 30581)
part #17032, 6-pin pigtail cable (AG-206 with lock sleeve), 2.4 m (DN 30582)
part #171512, 2-pin pigtail cable, Wet-pluggable (MCIL-2FS with MCDSL-F), 2.4 m (DN 32514)
part #171638, 3-pin pigtail cable, Wet-pluggable (MCIL-3FS with MCDSL-F), 2.4 m (DN 32646)
part #171368, 4-pin pigtail cable, Wet-pluggable (MCIL-4FS with MCDSL-F), 2.4 m (DN 32363)
part #171364, 4-pin pigtail cable, Wet-pluggable (MCIL-4MP with MCDSL-F), 2.4 m (DN 32365)
part #171442, 5-pin pigtail cable, Wet-pluggable (MCIL-5FS with MCDSL-F), 2.4 m (DN 32663)
part #171513, 6-pin pigtail cable, Wet-pluggable (MCIL-6FS with MCDSL-F), 2.4 m (DN 32515)
Data I/O Cables (not load bearing)
part #801225, data I/O Cable, 2.4 m, Standard connector (RMG-4FS) with DB-9S (DN 32421)
part #801374, data I/O cable, 2.4 m, Wet-pluggable (MCIL-4fS) with DB-9S (DN 32715)
part #801380, data I/O cable, 20 m shielded, Standard connector (RMG-4FS) with DB-9S (DN 31222)
part #801421, data I/O cable, 20 m shielded, Wet-pluggable connector (MCIL-4FS) with DB-9S (DN 32789)
part #171234, data I/O extension cable, 0.8 m, Standard connectors, RMG-4FS to RMG-4MP (DN 30587)
part # 17762, Data I/O extension cable, AG-206 to RMG-4MP, 0.84 m (DN 31605)
part # 801385, Data/Power interface cable, 2.4 m, Standard connector, RMG-4FS to DB-9S and red/black twisted wire leads (DN 32277)
part # 801206, Data/Power interface cable, 2.4 m, Wet-pluggable connector, MCIL-4FS to DB-9S and red/black twisted wire leads (DN 32366)
part # 801378, Data/Power interface cable, 20 m shielded, Standard connector, RMG-4FS to DB-9S and red/black twisted wire leads (DN 32720)
part # 801412, Data I/O cable (3-pin, no external power), Standard connector, RMG-3FS to DB-9S, 2.4 m (DN 32778)
part # 801366, Data I/O cable (3-pin, no external power), Wet-pluggable connector, MCIL-3FS to DB-9S, 2.4 m (DN 32702)
Load Bearing Data I/O Cables for hand-hauled, real-time profiling (maximum load 45 kg; minimum sheave diameter 20 cm; see Application Note 59 for proper use and limitations)
part #801150, load-bearing data cable, Standard connector, with DB-9S, 30 m (DN 32284)
part #801295, load-bearing data cable, Standard connector, with DB-9S, 50 m (DN 32284)
part #801140, load-bearing data cable, Standard connector, with DB-9S, 61 m (DN 32284)
part #801153, load-bearing data cable, Standard connector, with DB-9S, 100 m (DN 32284)
part #801301, load-bearing data cable, Standard connector, with DB-9S, 126 m (DN 32284)
part #801148, load-bearing data cable, Standard connector, with DB-9S, 183 m (DN 32284)
part #801371, load-bearing data cable, Wet-pluggable, with DB-9S, 30 m (DN 32643)
part #801372, load-bearing data cable, Wet-pluggable, with DB-9S, 60 m (DN 32643)
part #801337, load-bearing data cable, Wet-pluggable, with DB-9S, 100 m (DN 32643)
part #801338, load-bearing data cable, Wet-pluggable, with DB-9S, 200 m (DN 32643)
part #20200, USB to Serial Port Adapter, FTDI UC232R-10 (connects computers with USB ports to RS-232 instruments)
part #171888, DB-25S to DB-9P cable adapter (connects computer with 25-pin connector to Standard 9-pin data I/O cable provided with instruments)